Aquarian 1000Plus
The Aquarian
1000Plus satisfies basic electronic
local water level indication needs for boiler drums, feedwater
heaters and other liquid level applications. Based on the conductivity
probe technology now widely accepted in the industry, it has been
specifically designed to meet the industrys growing needs
and demand for a reliable, cost effective and versatile means
of sensing water levels in a variety of applications. Some of
which include generator coolant liquid level, blow down flash
tank and turbine extraction drains.
The electronic system in the Detection and
Verification (D&V) unit is connected to one to four probes
which can be mounted directly into pressure vessels or factory
mounted in a column. The D&V unit is capable of distinguishing
between water and steam even in water with conductivities as low
as 0.5 micromho. Diagnostics are provided to maximize system reliability
and redundant power supplies are incorporated to maintain system
operation should one of the dual AC supplies fail.
In addition to level sensing, the Aquarian
1000Plus provides output relays for each probe, which serve as
a system trip, alarm, or on-off control device. The system is
completely field configurable to provide maximum versatility.
Each Aquarian 1000Plus system includes one
D&V center and a maximum of four conductivity probes with
related hardware.
Key Features:
Up to 4 conductivity probes
Redundant power supplies
Wire continuity monitoring
Level fault monitoring
Local fault indication
Field configurable
Economical alternative to float level switches
|
 |
 |
 |
Specifications:
Supply
1/4A @ 120VAC
1/8A @ 240VAC
Contact Ratings
1
10A @ 24VDC (resistive)
10A @ 120VAC (resistive)
1/3 hp @ 120VAC
Enclosure
NEMA 4X
11 3/4" x 7 3/8" x 6 3/4"
Ambient Temperature
Electronics
32°F to 140°F (0°C to 60°C)
Conductivity Capability
0.5 micromho
Column Ratings
2
2000 psig @ 750°F
3000 psig @ 750°F
1 Form A or C contacts available
2 Other materials available for higher temps
|
|
|